期刊论文详细信息
BioMedical Engineering OnLine
Automatic method of analysis of OCT images in the assessment of the tooth enamel surface after orthodontic treatment with fixed braces
Robert Koprowski1  Monika Machoy2  Krzysztof Woźniak2  Zygmunt Wróbel1 
[1] Department of Biomedical Computer Systems, University of Silesia, Faculty of Computer Science and Materials Science, Institute of Computer Science, ul. Będzińska 39, Sosnowiec 41-200, Poland
[2] Department of Orthodontics, Pomeranian Medical University, al. Powstańców Wlkp. 72, Szczecin 70-111, Poland
关键词: Tooth enamel;    Segmentation;    Measurement Automation;    Orthodontic;    Image processing;   
Others  :  794867
DOI  :  10.1186/1475-925X-13-48
 received in 2014-01-14, accepted in 2014-04-07,  发布年份 2014
PDF
【 摘 要 】

Introduction

Fixed orthodontic appliances, despite years of research and development, still raise a lot of controversy because of its potentially destructive influence on enamel. Therefore, it is necessary to quantitatively assess the condition and therein the thickness of tooth enamel in order to select the appropriate orthodontic bonding and debonding methodology as well as to assess the quality of enamel after treatment and clean-up procedure in order to choose the most advantageous course of treatment. One of the assessment methods is computed tomography where the measurement of enamel thickness and the 3D reconstruction of image sequences can be performed fully automatically.

Material and method

OCT images of 180 teeth were obtained from the Topcon 3D OCT-2000 camera. The images were obtained in vitro by performing sequentially 7 stages of treatment on all the teeth: before any interference into enamel, polishing with orthodontic paste, etching and application of a bonding system, orthodontic bracket bonding, orthodontic bracket removal, cleaning off adhesive residue. A dedicated method for the analysis and processing of images involving median filtering, mathematical morphology, binarization, polynomial approximation and the active contour method has been proposed.

Results

The obtained results enable automatic measurement of tooth enamel thickness in 5 seconds using the Core i5 CPU M460 @ 2.5GHz 4GB RAM. For one patient, the proposed method of analysis confirms enamel thickness loss of 80 μm (from 730 ± 165 μm to 650 ± 129 μm) after polishing with paste, enamel thickness loss of 435 μm (from 730 ± 165 μm to 295 ± 55 μm) after etching and bonding resin application, growth of a layer having a thickness of 265 μm (from 295 ± 55 μm to 560 ± 98 μm after etching) which is the adhesive system. After removing an orthodontic bracket, the adhesive residue was 105 μm and after cleaning it off, the enamel thickness was 605 μm. The enamel thickness before and after the whole treatment decreased by about 125 μm.

Conclusions

This paper presents an automatic quantitative method for the assessment of tooth enamel thickness. This method has proven to be an effective diagnostic tool that allows evaluation of the surface and cross section of tooth enamel after orthodontic treatment with fixed thin-arched braces and proper selection of the methodology and course of treatment.

【 授权许可】

   
2014 Koprowski et al.; licensee BioMed Central Ltd.

【 预 览 】
附件列表
Files Size Format View
20140705073805665.pdf 4198KB PDF download
Figure 9. 80KB Image download
Figure 8. 151KB Image download
Figure 7. 156KB Image download
Figure 6. 57KB Image download
Figure 5. 344KB Image download
Figure 4. 123KB Image download
Figure 3. 64KB Image download
Figure 2. 51KB Image download
Figure 1. 64KB Image download
【 图 表 】

Figure 1.

Figure 2.

Figure 3.

Figure 4.

Figure 5.

Figure 6.

Figure 7.

Figure 8.

Figure 9.

【 参考文献 】
  • [1]Jones RS, Darling CL, Featherstone JD, Fried D: Remineralization of in vitro dental caries assessed with polarization-sensitive optical coherence tomography. J Biomed Opt 2006, 11(1):014016.
  • [2]Bishara SE, Oonsombat C, Soliman MM, Warren JJ, Laffoon JF, Ajlouni R: Comparison of bonding time and shear bond strength between a conventional and a new integrated bonding system. Angle Orthod 2005, 75(2):237-242.
  • [3]Buyukyilmaz T, Usumez S, Karaman AI: Effect of self-etching primers on bond strength-are they reliable? Angle Orthod 2003, 73:64-70.
  • [4]Bishara SE, Von Wald L, Laffoon JF, Warren JJ: Effect of a self-etch primer/adhesive on the shear bond strength of orthodontic brackets. Am J Orthod Dentofacial Orthop 2001, 119:621-624.
  • [5]Yamada R, Hayakawa T, Kasai K: Effect of using self-etching primer for bonding orthodontic brackets. Angle Orthod 2002, 7(6):558-564.
  • [6]Grubisa HS, Heo G, Raboud D, Glover KE, Major PW: An evaluation and comparison of orthodontic bracket bond strengths achieved with self-etching primer. Am J Orthod Dentofacial Orthop 2004, 126:213-219.
  • [7]Ryf S, Flury S, Palaniappan S, Lussi S, van Meerbeek S, Zimmerli B: Enamel loss and adhesive remnants following bracket removal and various clean-up procedures in vitro. Eur J Orthod 2012, 34(1):25-32.
  • [8]Bonetti GA, Zanarini M, Incerti Parenti S, Lattuca M, Marchionni S, Gatto MR: Evaluation of enamel surfaces after bracket debonding: An in-vivo study with scanning electron microscopy. Am J Orthod Dentofacial Orthop 2011, 140(5):6967-02.
  • [9]Colston BW, Sathyam US, DaSilva LB, Everett MJ: Dental OCT. Opt Express 1998, 3(6):230-238.
  • [10]Otis LL, Everett MJ, Sathyam US, Colston BW: Optical coherence tomography: a new imaging technology for dentistry. J Am Dent Assoc 2000, 131(4,5):11-14.
  • [11]Tao YC, Fried DJ: Near-infrared image-guided laser ablation of dental decay. J Biomed Opt 2009, 14(5):054045.
  • [12]Huang D, Swanson EA, Lin CP, Schuman JS, Stinson WG, Chang W, Hee MR, Flotte T, Gregory K, Puliafito CA, Fujimoto JG: Optical coherence tomography. Science 1991, 254(5035):1178-1181.
  • [13]Sumi Y, Ozawa N, Nagaosa S, Minakuchi S, Umemura O: Application of optical coherence tomography (OCT) to nondestructive inspection of dentures. Arch Gerontol Geriatr 2011, 53(2):237-241.
  • [14]Baek JH, Na J, Lee BH, Choi E, Son WS: Optical approach to the periodontal ligament under orthodontic tooth movement: a preliminary study with optical coherence tomography. Am J Orthod Dentofacial Orthop 2009, 135(2):252-259.
  • [15]Gracez AS, Suzuki SS, Ribeiro MS, Mada EY, Freitas AZ, Suzuki H: Biofilm retention by 3 methods of ligation on orthodontic brackets: a microbiologic and optical coherence tomography analysis. Am J Orthod Dentofacial Orthop 2011, 140(4):193-198.
  • [16]Fried D, Featherstone JD, Darling CL, Jones RS, Ngaotheppitak P, Bühler CM: Early caries imaging and monitoring with near-infrared light. Dent Clin N Am 2005, 49(4):771.
  • [17]Wu J, Fried D: High contrast near-infrared polarized reflectance images of demineralization on tooth buccal and occlusal surfaces at lambda = 1310 nm. Lasers Surg Med 2009, 41(3):208-213.
  • [18]Kang H, Darling CL, Fried D: Nondestructive monitoring of the repair of enamel artificial lesions by an acidic remineralization model using polarization-sensitive optical coherence tomography. Dent Mater 2012, 28(5):48894.
  • [19]Lee C, Darling CL, Fried D: Polarization-sensitive optical coherence tomographic imaging of artificial demineralization on exposed surfaces of tooth roots. Dent Mater 2009, 25(6):721-728.
  • [20]Kang H, Jiao JJ, Lee C, Le MH, Darling CL, Fried DJ: Nondestructive assessment of early tooth demineralization using cross-polarization optical coherence tomography. IEEE J Sel Top Quantum Electron 2010, 16(4):870-876.
  • [21]Van Waes H, Matter T, Krejci I: Three-dimensional measurement of enamel loss caused by bonding and debonding of orthodontic brackets. Am J Orthod Dentofacial Orthop 1997, 112:666-669.
  • [22]Otsu N: A threshold selection method from gray-level histograms. IEEE Trans Syst Man Cybern 1979, 9(1):62-66.
  • [23]Mishra A, Wong A, Bizheva K, Clausi DA: Intra-retinal layer segmentation in optical coherence tomography images. Opt Express 2009, 17(26):23719-23728.
  • [24]Lu S, Cheung C, Liu J, Lim S, Leung C, Wong T: Automated layer segmentation of optical coherence tomography images. IEEE Trans Biomed Eng 2010, 57(10):2605-2608.
  • [25]DeBuc C, Somfai GM: Early detection of retinal thickness changes in diabetes using optical coherence tomography. Med Sci Monit 2010, 16(3):MT15-MT21.
  • [26]Koprowski R, Wrobel Z: Identification of layers in a tomographic image of an eye based on the canny edge detection. Inf Technol Biomed Adv Intell Soft Comput 2008, 47:232-239.
  • [27]Koprowski R, Wróbel Z: Image processing in optical coherence tomography: using matlab. Katowice, Poland: University of Silesia; 2011. http://www.ncbi.nlm.nih.gov/books/NBK97169/ webcite
  • [28]Koprowski R, Wróbel Z: Layers recognition in tomographic eye image based on random contour analysis. Computer recognition systems 3. Adv Intell Soft Comput 2009, 57:471-478.
  • [29]Finke M, Parker DM, Jandt KD: Influence of soft drinks on the thickness and morphology of in situ acquired pellicle layer on enamel. J Colloid Interface Sci 2002, 251(2):263-270.
  • [30]Watari F: In situ quantitative analysis of etching process of human teeth by atomic force microscopy. J Electron Microsc (Tokyo) 2005, 54(3):299-308.
  • [31]Lorenzo MC, Portillo M, Moreno P, Montero J, García A, Santos-Del Riego SE, Albaladejo A: Ultrashort pulsed laser conditioning of human enamel: in vitro study of the influence of geometrical processing parameters on shear bond strength of orthodontic brackets. Lasers Med Sci 2013, 1:10.
  • [32]Wilder-Smith CH, Wilder-Smith P, Kawakami-Wong H, Voronets J, Osann K, Lussi A: Quantification of dental erosions in patients with GERD using optical coherence tomography before and after double-blind, randomized treatment with esomeprazole or placebo. Am J Gastroenterol 2009, 104(11):2788.
  • [33]Le MH, Darling CL, Fried D: Automated analysis of lesion depth and integrated reflectivity in PS-OCT scans of tooth demineralization. Lasers Surg Med 2010, 42(1):62.
  • [34]Korzynska A, Hoppe A, Strojny W: Investigation of a combined texture and contour method for segmentation of light microscopy cell images. In Proceedings of the Second IASTED International Conference on Biomedical Engineering. Anaheim, Calif. Calgary: Zurich ACTA Press; 2004:234-239.
  • [35]Korzynska A, Iwanowski M: Multistage morphological segmentation of bright-field and fluorescent microscopy images. Opt-Electron Rev 2012, 20(2):87-99.
  • [36]Siedlecki D, Nowak J, Zajac M: Placement of a crystalline lens and intraocular lens: retinal image quality. J Biomed Opt 2006, 11(5):054012.
  • [37]Porwik P: Efficient spectral method of identification of linear Boolean function. Control Cybern 2004, 33(4):663-678.
  • [38]Korus P, Dziech A: Efficient method for content reconstruction with self-embedding. IEEE Trans Image Process 2013, 22(3):1134-1147.
  • [39]Wilczyński S, Ptaszkiewicz M, Pierzchała E, Pilawa B, Swakoń J, Olko P: Electron paramagnetic resonance studies of gamma irradiated azithromycin. Curr Top in Biophysics 2008, 31:1-4.
  • [40]Tadeusiewicz R, Ogiela MR: Automatic understanding of medical images new achievements in syntactic analysis of selected medical images. Biocybern Biomed Eng 2002, 22(4):17-29.
  • [41]Wilczyński S, Pilawa B, Koprowski R, Wróbel Z, Ptaszkiewicz M, Swakoń J, Olko P: EPR studies of free radical decay and survival in gamma irradiated aminoglycoside antibiotics: sisomicin, tobramycin and paromomycin. Eur J Pharm Sci 2012, 45:251-262.
  文献评价指标  
  下载次数:132次 浏览次数:18次