会议论文详细信息
International Multi-Conference on Industrial Engineering and Modern technologies | |
Experimental Comparison of Construction Material Vapor Permeability in Case of Horizontal or Vertical Sample Position | |
Zubarev, K.P.^1 ; Gagarin, V.G.^2 | |
Department of Heat and Gas Supply and Ventilation, Moscow State University of Civil Engineering, Yaroslavskoye Shosse, 26, Moscow | |
129337, Russia^1 | |
Research Institute of Building Physics, Russian Academy of Architecture and Construction Science, Moscow | |
127238, Russia^2 | |
关键词: Coefficient values; Experimental comparison; Measuring height; Relative air humidities; Sample position; Section capacity; Test materials; Vapor permeability; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/463/3/032082/pdf DOI : 10.1088/1757-899X/463/3/032082 |
|
来源: IOP | |
![]() |
【 摘 要 】
The paper proposes a device for vapor permeability coefficient determination in case of vertical sample position. The device is a L-type section capacity with a window in upper part of long side of the capacity. A test sample of construction material is positioned vertically and sealed in the window. The capacity has built-in relative air humidity sensors distributed along capacity height. These sensors allow measuring height-average relative air humidity. Experimental vapor permeability coefficient values, obtained by means of the proposed device and by means of well-known wet cup method, have been compared. Rock wool has been used as a test material. As a result, wet cup method has been confirmed for vapor permeability coefficient determination for vertical enclosing structures.【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Experimental Comparison of Construction Material Vapor Permeability in Case of Horizontal or Vertical Sample Position | 362KB | ![]() |