3rd Annual Applied Science and Engineering Conference | |
Reduction in power consumption of refrigerator by using parallel expansion | |
工业技术;自然科学 | |
Berman, E.T.^1 ; Supriawan, D.^1 ; Komaro, M.^1 ; Mutaufiq, M.^1 | |
Department of Mechanical Engineering Education, Universitas Pendidikan Indonesia, Bandung, Indonesia^1 | |
关键词: Cooling load; Discharge pressures; Electrical power consumption; Expansion devices; Suction pressures; Test instruments; Working fluid; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/434/1/012173/pdf DOI : 10.1088/1757-899X/434/1/012173 |
|
来源: IOP | |
【 摘 要 】
This study aims to determine the reduction in power consumption of refrigerators by using parallel expansion. A refrigerator with a capacity of 120 litters has been used as a test instrument and R134a acts as a working fluid. Recording of refrigerator energy consumption is based on changes in cooling load temperature from range 3C to -3 C. The parameters observed during the test include suction pressure, discharge pressure, electric current, and weight of refrigerant circulated. The results indicate that installation of parallel expansion device on the refrigerator generates a decreased 1.5% - 4% of the electrical power consumption (ECP) so that it implicates for the save on power consumption required a refrigerator.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Reduction in power consumption of refrigerator by using parallel expansion | 450KB | download |