会议论文详细信息
Construmat 2018
Determining reinforcement coverage using an electromagnetic rebar detector
Cikrle, P.^1 ; Anton, O.^1 ; Kinclova, A.^1 ; Kocab, D.^1
Faculty of Civil Engineering, Brno University of Technology, Veveri 331/95, Brno
602 00, Czech Republic^1
关键词: Accurate estimation;    Electromagnetic detection;    Nondestructive methods;    Reinforcement spacing;    Research outcome;    State of the art;    Statistical evaluation;    Technical drawing;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/385/1/012009/pdf
DOI  :  10.1088/1757-899X/385/1/012009
来源: IOP
PDF
【 摘 要 】

Correct reinforcement is an essential part of constructing reinforced concrete structures. Errors in positioning, diameter, or coverage may result in defects, which is why it is necessary to make sure the reinforcement is implemented well. Even though electromagnetic detection is the most common non-destructive method for locating reinforcement in reinforced concrete, science literary sources hardly discuss it. The main reason is a lack of graphic test results - thus far the most common research outcomes have been photographs of lines drawn on the concrete surface or additions to technical drawings of the reinforcement. Only modern detectors expanded the possibilities of the method's application including graphic measurement records and a more accurate estimation of reinforcement diameter including corrections for adjacent reinforcement spacing. The paper focuses on the principle of measurement and practical examples of determining the position and coverage of reinforcement in reinforced-concrete structures using a state-of-the-art electromagnetic rebar detector - a Profometer PM-630. Aside from data recording and statistical evaluation during coverage measurement, modern instruments also allow the data to be exported and visualised.

【 预 览 】
附件列表
Files Size Format View
Determining reinforcement coverage using an electromagnetic rebar detector 688KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:35次