会议论文详细信息
International Conference and Exhibition in Advanced Materials and Microscopy 2017
Study Improving Performance of Centrifugal Compressor In Paiton Coal Fired Power Plant Unit 1 And 2
材料科学;物理学
Kusuma, Yuriadi^1 ; Permana, Dadang S.^1
Department of Mechanical Engeneering, Faculty of Engineering, Universitas Mercu Buana, Jakarta
11650, Indonesia^1
关键词: Coal-fired power plant;    Compressed air system;    Electric power;    Electricity-consumption;    Improving performance;    Power consumed;    Specific power consumption;    Utility systems;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/343/1/012030/pdf
DOI  :  10.1088/1757-899X/343/1/012030
学科分类:材料科学(综合)
来源: IOP
PDF
【 摘 要 】
The compressed air system becomes part of a very important utility system in a Plant, including the Steam Power Plant. In PLN'S coal fired power plant, Paiton units 1 and 2, there are four Centrifugal air compressor types, which produce compressed air as much as 5.652 cfm and with electric power capacity of 1200 kW. Electricity consumption to operate centrifugal compressor is 7.104.117 kWh per year. This study aims to measure the performance of Centrifugal Compressors operating in Paiton's coal fired power plant units 1 and 2. Performance Compressor is expressed by Specific Power Consumption (SPC) in kW/100 cfm. For this purpose, we measure the compressed air flow rate generated by each compressor and the power consumed by each compressor. The result is as follows Air Compressor SAC 2B : 15.1 kW/100 cfm, Air Compressor SAC 1B : 15.31 kW/100 cfm,Air Compressor SAC 1A : 16.3 kW/100 cfm and air Compressor SAC 2C : 18.19 kW/100 cfm. From the measurement result, air compressor SAC 2B has the best performance that is 15.1 kW / 100 cfm. In this study we analyze efforts to improve the performance of other compressors to at least match the performance of the SAC 2B air compressor. By increasing the Specific Power Consumption from others Compressor, it will get energy saving up to 284,165 kWh per year.
【 预 览 】
附件列表
Files Size Format View
Study Improving Performance of Centrifugal Compressor In Paiton Coal Fired Power Plant Unit 1 And 2 720KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:14次