会议论文详细信息
2019 5th International Conference on Energy Materials and Environment Engineering
Calculation and Analysis of Energy Consumption Index of Environmental Protection Facilities in Coal-fired Power Plant
能源学;生态环境科学
Li, Chao^1 ; Jiang, Chong^1 ; Qu, Li-Tao^1 ; Yu, Hong-Hai^1 ; Qi, Xiao-Hui^1 ; De-Xin, Wang^1 ; Du, Jia^1
Huadian Power Science Research Institute Co., Ltd., Shenyang
110180, China^1
关键词: Calculation results;    Coal fired units;    Coal-fired power plant;    Electricity-consumption;    Energy consumption index;    Energy consumption levels;    Energy efficiency improvements;    Generating unit;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/295/5/052053/pdf
DOI  :  10.1088/1755-1315/295/5/052053
学科分类:环境科学(综合)
来源: IOP
PDF
【 摘 要 】

Energy consumption of environmental protection facilities in coal-fired power plants is an important part of energy consumption of generating units. Taking 2 x 600 MW generating unit as an example, in this paper discusses the Energy Consumption Index Composition and Calculation Method of Environmental Protection Facilities. The results show that the energy consumption index for removal of unit quality pollutants can better reflect the energy consumption level of environmental protection facilities. The fan electricity consumption caused by resistance of environmental protection facilities is an important part of energy consumption. The calculation results can provide basic data and basis for energy consumption management and energy efficiency improvement of environmental protection facilities of coal-fired units.

【 预 览 】
附件列表
Files Size Format View
Calculation and Analysis of Energy Consumption Index of Environmental Protection Facilities in Coal-fired Power Plant 566KB PDF download