会议论文详细信息
2nd International Conference on New Material and Chemical Industry
Calculation and affection of pH value of different desulfurization and dehydration rates in the filling station based on Aspen Plus
材料科学;化学工业
Lv, J.X.^1 ; Wang, B.F.^1 ; Nie, L.H.^1 ; Xu, R.R.^1 ; Zhou, J.Y.^1 ; Hao, Y.J.^1
School of Petrochemical and Energetic Engineering, Zhejiang Ocean University, Zhoushan
316000, China^1
关键词: Anti-corrosive;    Calculation process;    Dehydration rates;    Desulfurization rate;    Effect of water;    Environmental pressures;    Gas stations;    Simulation process;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/292/1/012005/pdf
DOI  :  10.1088/1757-899X/292/1/012005
学科分类:材料科学(综合)
来源: IOP
PDF
【 摘 要 】

The simulation process of the whole CNG filling station are established using Aspen Plus V7.2. The separator (Sep) was used to simulate the desulfurization and dehydration equipment in the gas station, and the flash module separator Flash 2 was used to simulate the gas storage well with proper temperature and environmental pressure. Furthermore, the sensitivity module was used to analyse the behaviour of the dehydration and desulfurization rate, and the residual pH value of the gas storage wells was between 2.2 and 3.3. The results indicated that the effect of water content on pH value is higher than that of hydrogen sulphide in the environment of gas storage wells, and the calculation process of the pH value is feasible. Additionally, the simulation process provides basic data for the subsequent anticorrosive mechanism and work of gas storage well and has great potential for practical applications.

【 预 览 】
附件列表
Files Size Format View
Calculation and affection of pH value of different desulfurization and dehydration rates in the filling station based on Aspen Plus 491KB PDF download
  文献评价指标  
  下载次数:14次 浏览次数:22次