会议论文详细信息
Cryogenic Engineering Conference 2017
Serial testing of XFEL cryomodules: results of the cryogenic heat load measurements
材料科学;物理学
Böckmann, T.^1 ; Bozhko, Y.^1 ; Gay, W.^2 ; Halczynski, P.^2 ; Petersen, B.^1 ; Putselyk, S.^3 ; Schnautz, T.^1 ; Sienkiewicz, M.^2 ; Swierblewski, J.^2
Deutsches Elektronen-Synchrotron (DESY), Notkestrasse 85, Hamburg
22607, Germany^1
Instytut Fizyki Jadrowej (IFJ), Polskiej Akademii Nauk (PAN), Krakow
31-342, Poland^2
Ferchau Engineering GmbH, Butzweilerhof-Allee 4, Köln
50829, Germany^3
关键词: Cell cavity;    Dynamic heat;    First integral;    Helium II;    Load measurements;    Pulsed electron beams;    X-ray free electron lasers;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/278/1/012184/pdf
DOI  :  10.1088/1757-899X/278/1/012184
学科分类:材料科学(综合)
来源: IOP
PDF
【 摘 要 】

The European X-ray Free Electron Laser (XFEL) is in operation at DESY. The superconducting XFEL linac will produce pulsed electron beam at an energy of 17.5 GeV. The linac consists of 768 superconducting niobium 1.3 GHz nine cell cavities and 96 superconducting magnet packages assembled in 96 cryomodules. Each cryomodule is 12 m long and includes a 2 K helium II bath circuit for the cavities, and 5/8 and 40/80 K thermal radiation shields. Before being installed in the XFEL linac tunnel all cryomodules were tested in the Accelerator Module Test Facility (AMTF.) In this paper methods and results of static and dynamic heat load measurements of all XFEL cryomodules are reported. A comparison with first integral heat load measurements in the XFEL linac is given.

【 预 览 】
附件列表
Files Size Format View
Serial testing of XFEL cryomodules: results of the cryogenic heat load measurements 345KB PDF download