会议论文详细信息
Cryogenic Engineering Conference 2017
Gas propagation following a sudden loss of vacuum in a pipe cooled by He I and He II.
材料科学;物理学
Garceau, N.^1,2 ; Guo, W.^1,2 ; Dodamead, T.^1,2
National High Magnetic Field Laboratory, Tallahassee
FL
32310, United States^1
Mechanical Engineering Department, FAMU-FSU College of Engineering, Tallahassee
FL
32310, United States^2
关键词: Catastrophic loss;    Cryogenic system;    Front propagation;    Heat transfer mechanism;    National High Magnetic Field Laboratory;    Propagation lengths;    Superconducting particles;    Thermal counterflow;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/278/1/012068/pdf
DOI  :  10.1088/1757-899X/278/1/012068
学科分类:材料科学(综合)
来源: IOP
PDF
【 摘 要 】

Many cryogenic systems around the world are concerned with the sudden catastrophic loss of vacuum for cost, preventative damage, safety or other reasons. The experiments in this paper were designed to simulate the sudden vacuum break in the beam-line pipe of a liquid helium cooled superconducting particle accelerator. This paper expands previous research conducted at the National High Magnetic Field Laboratory and evaluates the differences between normal helium (He I) and superfluid helium (He II). For the experiments, a straight pipe and was evacuated and immersed in liquid helium at 4.2 K and below 2.17 K. Vacuum loss was simulated by opening a solenoid valve on a buffer tank filled nitrogen gas. Gas front arrival was observed by a temperature rise of the tube. Preliminary results suggested that the speed of the gas front through the experiment decreased exponentially along the tube for both normal liquid helium and super-fluid helium. The system was modified to a helical pipe system to increase propagation length. Testing and analysis on these two systems revealed there was minor difference between He I and He II despite the difference between the two distinct helium phases heat transfer mechanisms: convection vs thermal counterflow. Furthermore, the results indicated that the temperature of the tube wall above the LHe bath also plays a significant role in the initial front propagation. More systematic measurements are planned in with the helical tube system to further verify the results.

【 预 览 】
附件列表
Files Size Format View
Gas propagation following a sudden loss of vacuum in a pipe cooled by He I and He II. 673KB PDF download
  文献评价指标  
  下载次数:11次 浏览次数:26次