Renovation and design of double casement windows with regard to the occurrence of water vapour condensation or mould on the interior surface of the window jamb
Kudrnacova, L.^1 ; Balik, L.^1
Klokner Institute, Czech Technical University in Prague, Solinova 7, Prague, Czech Republic^1
关键词: Casement windows;    External insulations;    Interior surfaces;    Temperature and relative humidity;    Thermal model;    Water vapour;    Window casements;    Window designs;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/251/1/012101/pdf
DOI  :  10.1088/1757-899X/251/1/012101
来源: IOP
PDF
【 摘 要 】

The condensation of water vapour on the interior surface is an indicator of construction dysfunction or ignoring of the surroundings temperature and relative humidity. This paper deals with analysis of the occurrence of condensation on the jamb of double casement windows (windows with two window casements). More precisely, this is a surface in the interior where water vapour condensation or mould occur. For the renovation of existing double casement windows, there are different solutions based on window design: Application of double insulating glazing on the interior window casement, application of double insulating glazing on the exterior casement, or installation of a simple window. We first describe measurement of an existing double casement window located in a mountain cottage. Second, the results and comparison of 2D thermal model of different types of double casement window construction. Also, the external insulation of the peripheral wall was included in the model.

【 预 览 】
附件列表
Files Size Format View
Renovation and design of double casement windows with regard to the occurrence of water vapour condensation or mould on the interior surface of the window jamb 800KB PDF download
  文献评价指标  
  下载次数:11次 浏览次数:15次