World Multidisciplinary Civil Engineering-Architecture-Urban Planning Symposium - WMCAUS | |
Effect of Autoclaved Aerated Concrete Modification with High-Impact Polystyrene on Sound Insulation | |
土木建筑工程 | |
Brelak, Sylwia^1 ; Dachowski, Ryszard^1 | |
Kielce University of Technology, al. Tysiclecia Pastwa Polskiego 7, Kielce | |
25-314, Poland^1 | |
关键词: Autoclaved aerated concrete; Conventional products; High impact polystyrene; Low density; Physical and mechanical properties; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/245/2/022089/pdf DOI : 10.1088/1757-899X/245/2/022089 |
|
学科分类:土木及结构工程学 | |
来源: IOP | |
【 摘 要 】
Autoclaved aerated concrete is one of the most commonly used building materials. Its advantages include low density, high thermal insulation capacity and high fire resistance. It has a relatively high compressive strength, though not high enough to be able to compete with other building materials in this respect. One of the directions leading to the improvement of physical and mechanical properties of autoclaved aerated concrete is the modification of its composition. A noticeable effect of pulverized high-impact polystyrene (improved compressive strength and water absorption) was relevant for the decision to continue the study of its effects. This paper discusses the effect of high-impact polystyrene on sound insulation in AAC products. The tests demonstrated a positive influence of the modifier on AAC sound insulation enhancement. Results from the tests performed on HIPS-modified AAC products were showed and compared with the properties of conventional products. The effect of the polymer on the microstructure of the products obtained was described briefly.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Effect of Autoclaved Aerated Concrete Modification with High-Impact Polystyrene on Sound Insulation | 373KB | download |