会议论文详细信息
2017 3rd International Conference on Applied Materials and Manufacturing Technology
Analysis of blood cell particles in axial blood pump by using computational fluid dynamics/discrete element method model
Lizhi, Cheng^1,2 ; Jianping, Tan^1 ; Zhong, Yun^1 ; Yan, Xu^2
School of Mechanical and Electrical Engineering, Central South University, Changsha
410083, China^1
Department of Mechanical and Electrical Engineering, Changsha University, Changsha
410022, China^2
关键词: Axial blood pumps;    Blood cells;    Collision rate;    Element method;    Guide vane;    Motion law;    Performance indices;    Wall surfaces;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/242/1/012104/pdf
DOI  :  10.1088/1757-899X/242/1/012104
来源: IOP
PDF
【 摘 要 】
Computational fluid dynamics/discrete element method (CFD-DEM) model was used to investigate the microscopic motion law of blood cells in a blood pump. The macro-hydrostatic performance indexes of the blood pump, as well as the characteristics of motion, collision. Result showed that collision among the blood cells mainly occurred at the front guide and the back guide, and the collision rate between the blood cells and the wall surface was 2.3 times the collision rate among the blood cells at the front guide vane area of the vane rotor.
【 预 览 】
附件列表
Files Size Format View
Analysis of blood cell particles in axial blood pump by using computational fluid dynamics/discrete element method model 235KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:25次