Experimental Investigation of Tensile Test on Connection of Cold-formed Cut-curved Steel Section
Mohd Sani, Mohd Syahrul Hisyam^1 ; Muftah, Fadhluhartini^1 ; Abdul Rahman, Nurul Farraheeda^1 ; Muda, Mohd Fakri^1
Faculty of Civil Engineering, Universiti Teknologi Mara, Cawangan Pahang, Kampus Jengka, Bandar Jengka, Pahang
26400, Malaysia^1
关键词: Cold-formed steel;    Compression effects;    Connection method;    Experimental investigations;    Non-structural components;    Strengthening methods;    Universal testing machines;    Welding specimens;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/226/1/012010/pdf
DOI  :  10.1088/1757-899X/226/1/012010
来源: IOP
PDF
【 摘 要 】

Cold-formed steel (CFS) is widely used as structural and non-structural components such as roof trusses and purlin. A CFS channel section with double intermediate web stiffener and lipped is chosen based on the broader usage in roof truss construction. CFS section is cut to form cold-formed pre-cut-curved steel section and lastly strengthened by several types of method or likely known as connection to establish the cold-formed cut-curved steel (CFCCS) section. CFCCS is proposed to be used as a top chord section in the roof truss system. The CFCCS is to resist the buckling phenomena of the roof truss structure and reduced the compression effect on the top chord. The tensile test connection of CFCCS section, especially at the flange element with eight types of connection by welding, plate with self-drilling screw and combination is investigated. The flange element is the weakest part that must be solved first other than the web element because they are being cut totally, 100% of their length for curving process. The testing is done using a universal testing machine for a tensile load. From the experiment, specimen with full welding has shown as a good result with an ultimate load of 13.37 kN and reported having 35.41% when compared with normal specimen without any of connection methods. Furthermore, the experimental result is distinguished by using Eurocode 3. The failure of a full welding specimen is due to breaking at the welding location. Additionally, all specimens with either full weld or spot weld or combination failed due to breaking on weld connection, but specimen with flange plate and self-drilling screw failed due to tilting and bearing. Finally, the full welding specimen is chosen as a good connection to perform the strengthening method of CFCCS section.

【 预 览 】
附件列表
Files Size Format View
Experimental Investigation of Tensile Test on Connection of Cold-formed Cut-curved Steel Section 469KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:16次