会议论文详细信息
26th International Cryogenic Engineering Conference & International Cryogenic Materials Conference 2016
Development of a valved non-lubricated linear compressor for compact 2K Gifford-McMahon cryocoolers
材料科学;物理学
Hiratsuka, Y.^1 ; Bao, Q.^1 ; Xu, M.^1
Technology Research Center, Sumitomo Heavy Industries, Ltd., 2-1-1 Yato-cho, Nishitokyo-shi, Tokyo
188-8585, Japan^1
关键词: Compressor efficiency;    Cooling applications;    Cooling performance;    Information and communications technology;    Power consumption reduction;    Semiconductor systems;    Sumitomo heavy industries;    Superconducting single-photon detectors;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/171/1/012072/pdf
DOI  :  10.1088/1757-899X/171/1/012072
学科分类:材料科学(综合)
来源: IOP
PDF
【 摘 要 】

Recently, a new, compact Gifford-McMahon (GM) cryocooler for cooling superconducting single photon detectors (SSPD) has been developed and reported by Sumitomo Heavy Industries, Ltd. (SHI) [1]. It was reported that National Institute of Information and Communications Technology (NICT) developed a multi-channel SSPD system in which two or more channels were mounted on a GM cryocooler, and achieved a world-top-class performance [2]. However, the applications of such SSPD system were restricted due to its relatively large size and power consumption compared with a semiconductor system. Owing to the development of an SSPD system with a portable cryocooler system which can be installed in a vehicle, it is possible to apply such system to the optical communication of AdHoc [3], and to flexibly construct a large capacity optical line in a time of disaster. For such system, the size and power consumption reduction becomes indispensable. The objective is to reduce the total height of the expander by 33% relative to the existing RDK-101 GM expander and to reduce the total volume of the compressor unit by 50% relative to the existing CNA-11 compressor. In addition, considering the targeted cooling application, we set the design temperature targets of the first and the second stages to 1 W and 20 mW of heat load at 60 K and 2.3 K, respectively. In 2015, Hiratsuka reported that a new valved non-lubricated compressor was developed for a 2K GM cryocooler [4]. The cooling performance of a 2K GM expander operated by an experimental unit of the linear compressor was measured, and preliminary experiments were conducted. No-load temperature was 2.19 K, with 1 W and 14 mW heat load, the temperature was 48 K at the first stage and 2.3 K at the second stage, with an input power of about 1.2 kW. After that, the compressor efficiency has been improved by reducing losses, and the compressor input power has been reduced by 25%. The detailed experimental results are discussed in this paper.

【 预 览 】
附件列表
Files Size Format View
Development of a valved non-lubricated linear compressor for compact 2K Gifford-McMahon cryocoolers 832KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:17次