Performance estimation of an oil-free linear compressor unit for a new compact 2K Gifford-McMahon cryocooler
材料科学;物理学
Hiratsuka, Y.^1 ; Bao, Q.^1 ; Xu, M.Y.^1
Technology Research Center, Sumitomo Heavy Industries, Ltd., 2-1-1, Yato-cho, Nishitokyo-city, Tokyo
188-8585, Japan^1
关键词: Cooling applications;    Information and communications technology;    Oil-free compressors;    Performance estimation;    Power consumption reduction;    Sumitomo heavy industries;    Superconducting single-photon detectors;    Vibration characteristics;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/278/1/012050/pdf
DOI  :  10.1088/1757-899X/278/1/012050
学科分类:材料科学(综合)
来源: IOP
PDF
【 摘 要 】

Since 2012, a new, compact Gifford-McMahon (GM) cryocooler for cooling superconducting single photon detectors (SSPD) has been developed and reported by Sumitomo Heavy Industries, Ltd. (SHI). Also, it was reported that National Institute of Information and Communications Technology (NICT) developed a multi-channel, conduction-cooled SSPD system. However, the size and power consumption reduction becomes indispensable to apply such a system to the optical communication of AdHoc for a mobile system installed in a vehicle. The objective is to reduce the total height of the expander by 33% relative to the existing RDK-101 GM expander and to reduce the total volume of the compressor unit by 50% relative to the existing CNA-11 compressor. In addition, considering the targeted cooling application, we set the design cooling capacity targets of the first and the second stages 1 W at 60 K and 20 mW at 2.3 K respectively. In 2016, Hiratsuka et al. reported that an oil-free compressor was developed for a 2K GM cryocooler. The cooling performance of a 2K GM expander driven by an experimental unit of the linear compressor was measured. No-load temperature less than 2.1 K and the cooling capacity of 20 mW at 2.3 K were successfully achieved with an electric input power of only 1.1 kW. After that, the compressor capsule and the heat exchanger, etc. were assembled into one enclosure as a compressor unit. The total volume of the compressor unit and electrical box was significantly reduced to about 38 L, which was close to the target of 35 L. Also, the sound noise, vibration characteristics, the effect of the compressor unit inclination and the ambient temperature on the cooling performance, were evaluated. The detailed experimental results are discussed in this paper.

【 预 览 】
附件列表
Files Size Format View
Performance estimation of an oil-free linear compressor unit for a new compact 2K Gifford-McMahon cryocooler 2435KB PDF download
  文献评价指标  
  下载次数:13次 浏览次数:19次