会议论文详细信息
International Conference on Applied Sciences 2016 | |
Vibration analysis of a hydro generator for different operating regimes | |
Haiegan, C.^1 ; Pdureanu, I.^2 ; Jurcu, M.^2 ; Nedeloni, M.D.^1 ; Hamat, C.O.^2 ; Chioncel, C.P.^1 ; Trocaru, S.^3 ; Vasile, O.^4 ; Bdescu, O.^5 ; Micliuc, D.^1 ; Nedeloni, L.^2 ; Bra, A.^2 ; Haiegan, L.^2 | |
Eftimie Murgu University of Resita, Department of Electric Engineering and Informatics, Traian Vuia str., no. 1-4, Resita | |
320085, Romania^1 | |
Eftimie Murgu University of Resita, Department of Mechanical and Materials Engineering, Traian Vuia str., no. 1-4, Resita | |
320085, Romania^2 | |
University of Bucharest, Faculty of Physics, Atomitilor str., no. 405, Bucuresti | |
077125, Romania^3 | |
Politehnica University of Bucharest, Department of Mechanics, Splaiul Independentei Str., No. 313, Bucuresti | |
060042, Romania^4 | |
Babe-Bolyai University, Department of Educational Science, Sindicatelor str., no. 7, Cluj-Napoca | |
400015, Romania^5 | |
关键词: Hydro generator; Hydropower plants; Load mode; Off-load; Operating regimes; Romania; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/163/1/012030/pdf DOI : 10.1088/1757-899X/163/1/012030 |
|
来源: IOP | |
【 摘 要 】
Based on experimental measurements, this paper presents the vibration analysis of a hydro generator that equips a Kaplan hydraulic turbine of a Hydropower plant in Romania. This analysis means vibrations measurement to different operating regimes of the hydro generator respectively before installing it and into operation, namely putting off load mode (unexcited and excited) respectively putting on load mode. By comparing, through the experimental results obtained before and after the operation of hydro aggregates are observed vibrations improvements.