【 摘 要 】

The article describes the corrosion test of steel of the brand 20 in the stratal water. To increase corrosion resistance as a corrosion inhibitor the concentrate waste emulsion of the mark "Incam- 1" was provided. The article presents studies of the corrosion rate with different dosages of corrosion inhibitor in the stratal water. Based on these research results are revealed that the degree of protection of steel is 27% at a dosage of 3.8 g / dm3.

【 预 览 】
附件列表
Files Size Format View
Waste of cleaning emulsion sewage as inhibitors of steel corrosion 688KB PDF download