会议论文详细信息
International Conference on Applied Sciences 2015
Study of thermal regimes of an electric resistance furnace using AT-503 controller
Iagr, A.^1 ; Popa, G.N.^1 ; Dini, C.M.^1
Politehnica University of Timisoara, Department of Electrical Engineering and Industrial Informatics, 5 Revolution Street, Hunedoara
331128, Romania^1
关键词: Following control;    Furnace temperatures;    Heating and cooling;    K-type thermocouples;    Low temperatures;    Temperature controllers;    Temperature measuring;    Thermal imagers;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/106/1/012006/pdf
DOI  :  10.1088/1757-899X/106/1/012006
来源: IOP
PDF
【 摘 要 】

In this paper were studied some thermal regimes of a low-temperature electric resistance furnace, with indirect heating. To determine the heat losses was used a thermal imager, which achieved a global image of the thermal field inside the furnace and upon the carcass. Thermal images of the furnace carcass revealed the following areas of heat losses greater than admissible in steady-state: furnace door, temperature measuring point and bonding areas of furnace metal carcass. To determine dead time and time constants were analyzed heating and cooling of the furnace until reaching the steady-state. In the experiments has been used AT-503 temperature controller, equipped with a K type thermocouple. Were analyzed following control methods of furnace temperature: on/off with hysteresis of 5°C and autotunig.

【 预 览 】
附件列表
Files Size Format View
Study of thermal regimes of an electric resistance furnace using AT-503 controller 1241KB PDF download
  文献评价指标  
  下载次数:16次 浏览次数:27次