7th International Conference on Cooling & Heating Technologies | |
Analysis of the Earthquake Impact towards water-based fire extinguishing system | |
材料科学;物理学 | |
Lee, J.^1 ; Hur, M.^2 ; Lee, K.^1 | |
Dept. of Information and Telecommunications Engineering, Incheon National University, Incheon, Korea, Republic of^1 | |
Faculty of Fire and Safety, Woosong College, Korea, Republic of^2 | |
关键词: Design of buildings; Earthquake response; Extinguishing systems; Fire fighting facilities; Fire-extinguishing systems; Performance requirements; Seismic design categories; Seismic Performance; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/88/1/012041/pdf DOI : 10.1088/1757-899X/88/1/012041 |
|
学科分类:材料科学(综合) | |
来源: IOP | |
【 摘 要 】
Recently, extinguishing system installed in the building when the earthquake occurred at a separate performance requirements. Before the building collapsed during the earthquake, as a function to maintain a fire extinguishing. In particular, the automatic sprinkler fire extinguishing equipment, such as after a massive earthquake without damage to piping also must maintain confidentiality. In this study, an experiment installed in the building during the earthquake, the water-based fire extinguishing saw grasp the impact of the pipe. Experimental structures for water-based fire extinguishing seismic construction step by step, and then applied to the seismic experiment, the building appears in the extinguishing of the earthquake response of the pipe was measured. Construction of acceleration caused by vibration being added to the size and the size of the displacement is measured and compared with the data response of the pipe from the table, thereby extinguishing water piping need to enhance the seismic analysis. Define the seismic design category (SDC) for the four groups in the building structure with seismic criteria (KBC2009) designed according to the importance of the group and earthquake seismic intensity. The event of a real earthquake seismic analysis of Category A and Category B for the seismic design of buildings, the current fire-fighting facilities could have also determined that the seismic performance. In the case of seismic design categories C and D are installed in buildings to preserve the function of extinguishing the required level of seismic retrofit design is determined.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Analysis of the Earthquake Impact towards water-based fire extinguishing system | 1063KB | download |