会议论文详细信息
30th International Conference on Photonic, Electronic, and Atomic Collisions | |
Upgrade of the Main Magnetic Focus Ion Trap in Giessen | |
Keil, Marc^1 ; Schippers, Stefan^1 ; Müller, Alfred^2 ; Borovik, Alexander^1 | |
I. Physikalisches Institut, Justus-Liebig-Universität Gießen, Giessen | |
35392, Germany^1 | |
Institut für Atom- und Molekülphysik, Justus-Liebig-Universität Gießen, Giessen | |
35392, Germany^2 | |
关键词: Ion species; Ion traps; Parent materials; | |
Others : https://iopscience.iop.org/article/10.1088/1742-6596/875/10/092027/pdf DOI : 10.1088/1742-6596/875/10/092027 |
|
来源: IOP | |
【 摘 要 】
Synopsis The Main Magnetic Focus Ion Trap installed in Giessen is being upgraded aiming at the extension of the range of producible ion species. The presently reported effort includes the installation of a system for extra fine-dosed introduction of gaseous parent materials into the trap region and the arrangement for the possibility of periodic dumping of the ion trap.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Upgrade of the Main Magnetic Focus Ion Trap in Giessen | 257KB | download |