会议论文详细信息
8th International Particle Accelerator Conference
Development of 3.95 MeV X-band linac-driven x-ray combined neutron source
Bereder, J.M.^1 ; Mitsuya, Y.^1 ; Takahashi, Y.^1 ; Dobashi, K.^1 ; Uesaka, M.^1 ; Kusano, J.^2 ; Tanaka, Y.^3 ; Oshima, Y.^4 ; Ishida, M.^4
University of Tokyo, 7-3-1, Bunkyou-ku, Tokyo
113-8654, Japan^1
Accuthera Inc., 2-22, Shirakata-shirane, Tokai-mura, Naka-gun, Ibaraki
319-1188, Japan^2
Institute of Industrial Science, 4-6-1, Komaba, Meguro-ku, Tokyo
153-8505, Japan^3
Public Works Research Institute, 1-6, Minamihara, Tsukuba-shi, Ibaraki
305-8516, Japan^4
关键词: Conventional methods;    High energy X ray;    Inspection system;    Internal flaws;    Moisture distribution;    Neutron backscattering;    Non-destructive inspection methods;    X-band linac;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/874/1/012104/pdf
DOI  :  10.1088/1742-6596/874/1/012104
来源: IOP
PDF
【 摘 要 】

The existing non-destructive inspection method employed for concrete structures uses high energy X-rays to detect internal flaws in concrete structures and iron reinforcing rods. In addition to this conventional method, the authors are developing an innovative inspection system that uses a mobile compact linac-driven neutron source that utilizes neutron backscattering, to measure the moisture distribution in concrete structures and estimate the corrosion probability distribution of iron reinforcing rods.

【 预 览 】
附件列表
Files Size Format View
Development of 3.95 MeV X-band linac-driven x-ray combined neutron source 1438KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:62次