会议论文详细信息
Wake Conference 2017 | |
Performance and Equivalent Loads of Wind Turbines in Large Wind Farms | |
Andersen, Soren J.^1 ; Sorensen, Jens N.^1 ; Mikkelsen, Robert F.^1 | |
DTU Wind Energy, Technical University of Denmark, Lyngby | |
2800, Denmark^1 | |
关键词: Effective power; Equivalent load; Fully-coupled; Moment load; Operating condition; Operational conditions; Power production; Rated wind speed; | |
Others : https://iopscience.iop.org/article/10.1088/1742-6596/854/1/012001/pdf DOI : 10.1088/1742-6596/854/1/012001 |
|
来源: IOP | |
【 摘 要 】
Ten simulations of large wind farms have been performed using a fully coupled LES and aero-elastic framework to form a database of full turbine operational conditions in terms of both production and loads. The performance is examined in terms of averaged power production and thrust, as well as 10min equivalent flapwise bending, yaw, and tilt moment loads. Certain scenarios operating below rated wind speed shows unexpected peaks in the loads. The influence on the operating conditions are examined for various parameters and compared relative to an effective power production per area.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Performance and Equivalent Loads of Wind Turbines in Large Wind Farms | 2470KB | download |