PIN-diode diagnostics of pulsed electron beam for high repetition rate mode | |
Egorov, Ivan^1 ; Xiao, Yu^2 ; Poloskov, Artem^1 | |
Institute of High Technology Physics, Tomsk Polytechnic University, 2a Lenin Avenue, Tomsk | |
634028, Russia^1 | |
School of Physics and Nuclear Energy Engineering, Beihang University, No.37 Xueyuan Road, Beijing | |
100191, China^2 | |
关键词: Accelerating voltages; Electron-beam parameters; High repetition rate; Operating parameters; Operating principles; Pulsed electron beams; Reference signals; Repetitive operations; | |
Others : https://iopscience.iop.org/article/10.1088/1742-6596/830/1/012044/pdf DOI : 10.1088/1742-6596/830/1/012044 |
|
来源: IOP | |
【 摘 要 】
This work describes the operating principle and test results of the diagnostics for measuring the pulsed electron beam parameters under repetitive operation mode. The diagnostics is based on a PIN-diode, which is used as a bremsstrahlung detector. The signal from a PIN-diode was converted to a pseudo constant voltage signal which can be measured by a conventional voltmeter. Then the signal acquired by the voltmeter was compared with a reference signal indicating the normal operating regime of the accelerator, thus information about the shot-to-shot reproducibility of the electron beam parameters was given. The system was developed and tested for the ASTRA-M accelerator with the following operating parameters: 470 kV accelerating voltage, 120 ns beam duration and up to 50 pulses per second repetition rate.