会议论文详细信息
10th Asia Plasma and Fusion Association Conference
Preliminary Results from Electron Cyclotron Measurements at SST-1
Siju, Varsha^1 ; Shukla, Praveena^1 ; Raval, Jayesh^1 ; Shankara, Joisa Y.^1 ; Pathak, S.K.^1
Institute for Plasma Research, Bhat, Gandhinagar
382 428, India^1
关键词: Electron cyclotron emission;    Electron cyclotrons;    Heterodyne radiometer;    Measurements of;    Noise temperature;    Radiation temperature;    Second harmonics;    Spatial resolution;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/823/1/012057/pdf
DOI  :  10.1088/1742-6596/823/1/012057
来源: IOP
PDF
【 摘 要 】
An 8-channel heterodyne radiometer system is developed and installed for the measurements of second harmonic electron cyclotron emission (ECE) at magnetic field of 1.5 T at SST-1. This system covers a spectral range of 75.4 to 84.5 GHz at a spatial resolution of less than 1 cm, sensitivity of 9.51 x 106V/W. The calculated noise temperature of the system is 1.66 eV. The system is calibrated using Hot/cold technique. This paper presents the preliminary observations of the heterodyne radiometer system at SST-1 and the measured radiation temperature.
【 预 览 】
附件列表
Files Size Format View
Preliminary Results from Electron Cyclotron Measurements at SST-1 1415KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:78次