Preliminary Design of O-mode Radiometer for ITER ECE Diagnostic
Danani, S.^1 ; Pandya, H.K.B.^1 ; Kumar, Ravinder^1 ; Austin, M.E.^2 ; Udintsev, V.S.^3 ; Kumar, Vinay^1
ITER-India, Institute for Plasma Research, Bhat, Gandhinagar
382 428, India^1
Fusion Research Center, University of Texas at Austin, Austin
TX, United States^2
ITER Organization Route de Vinon sur Verdon, StPaul-Lez-Durance
13115, France^3
关键词: Electron cyclotron emission;    Heterodyne radiometer;    Plasma cross section;    Plasma electron temperatures;    Technological challenges;    Temperature profiles;    Waveguide diplexers;    Wide frequency bands;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/823/1/012034/pdf
DOI  :  10.1088/1742-6596/823/1/012034
来源: IOP
PDF
【 摘 要 】
The ITER Electron Cyclotron Emission (ECE) diagnostic system will provide information about plasma electron temperature and its fluctuations and other important plasma parameters which are required for plasma control and physics studies. The temperature profile measurement in the first harmonic ECE frequency range from 122-230 GHz (for BT= 5.3 T) is obtained by using an O-mode heterodyne radiometer. It is difficult to cover this wide frequency band by one radiometer, due to technological challenges in achieving wide bandwidth for the mixers. So, the present radiometer design has been optimized by considering four receivers, each of bandwidth ∼ 30 GHz which can provide reliable temperature measurements. The splitting of frequency band into four receiver bands is efficiently achieved by considering a combination of quasi-optical and waveguide diplexers, optimizing power loss and cross-talk between the channels. The target spatial resolution of a/30, where "a" is the minor radius of the plasma cross section, is achieved by choosing Radiometer IF filter bandwidth of 1-2 GHz. Further, the radiometer is designed to achieve noise temperature
【 预 览 】
附件列表
Files Size Format View
Preliminary Design of O-mode Radiometer for ITER ECE Diagnostic 1652KB PDF download
  文献评价指标  