This article is devoted to the experimental study of heat transfer in a longitudinal glow discharge. The discharge was ignited in the discharge chamber (DC), consisting of a glass tube 10 mm in diameter and two electrodes. Copper electrodes were placed in the side branches, so that the average distance between them was 9 cm. The discharge pressure was varied in the range of P = (2.5 - 8.5) kPa. The air flow rate was varied from zero to G = 0.06 g / s. Current was varied in the range of I = (30-80) mA. Current-voltage characteristics of the discharge had falling form, and the voltage was varied in the range of U = (1-2) kV. The temperature of neutral particles in the plasma glow discharge was measured by six thermocouples, which were insertedon radius of DC. The aim of the article was to compare achieved experiment data with theoretical studies: recombination and diffusion plasma models.