An experimental work on wireless structural health monitoring system applying on a submarine model scale
Nugroho, W.H.^1 ; Purnomo, N.J.H.^1 ; Soedarto, T.^2
Pusat Teknologi Rekayasa Industri Maritim, BPPT, Komp. ITS Sukolilo, Surabaya, Indonesia^1
Balai Teknologi Hidrodinamika, BPPT, Komp. ITS Sukolilo, Surabaya, Indonesia^2
关键词: Communication signals;    Data-communication;    Detection capability;    Elastic modeling;    Health monitoring system;    Hull structures;    Wireless communication technology;    Wireless structural health monitoring systems;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/776/1/012094/pdf
DOI  :  10.1088/1742-6596/776/1/012094
来源: IOP
PDF
【 摘 要 】

This paper presents an experimental work to monitor the health of submarine hull structures using strain sensors and wireless communication technology. The monitored - submarine hull was built in a hydro elastic model scale 1: 30 with a steel bar backbone and tested on water tank of Indonesian Hydrodynamic Laboratory (IHL). Specifically, this health monitoring system for the submarine model was developed using wireless modems, data communication software and conventional strain sensors. This system was used to monitor the loads on a steel bar backbone of the running submarine model from the edge of the water tank. Commands were issued from a notebook to instruct the health monitoring system to acquire data from sensors mounted externally to the steel bar. Data from measurements made on the structure are then transmitted wirelessly back to a notebook computer for processing and analysis. The results of the tank test have been validated and showed no loss of communication signal over an area of the tank. This work also presents a potential use of involving complete automation of this system with an in-service structure coupled with an on-line warning/damage detection capability.

【 预 览 】
附件列表
Files Size Format View
An experimental work on wireless structural health monitoring system applying on a submarine model scale 1168KB PDF download
  文献评价指标  
  下载次数:11次 浏览次数:25次