会议论文详细信息
8th Brazilian Congress on Metrology | |
Uncertainty estimation in the determination of metals in superficial water by ICP-OES | |
Faustino, Mainara G.^1 ; Marques, Joyce R.^1 ; Monteiro, Lucilena R.^1 ; Stellato, Thamiris B.^1 ; Soares, Sabrina M. V.^1 ; Silva, Tatiane B. S. C.^1 ; Da Silva, Douglas B.^1 ; Pires, Maria Aparecida F.^1 ; Cotrim, Marycel E. B.^1 | |
Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP), Cidade Universitária, Avenida Lineu Prestes, 2242, São Paulo | |
SP | |
05508-000, Brazil^1 | |
关键词: Analytical curves; Measurement uncertainty; Optical emission spectrometry; Recovery methods; Superficial water; Uncertainty contributions; Uncertainty estimation; Validation study; | |
Others : https://iopscience.iop.org/article/10.1088/1742-6596/733/1/012032/pdf DOI : 10.1088/1742-6596/733/1/012032 |
|
来源: IOP | |
【 摘 要 】
From validation studies, it was possible to estimate a measurement uncertainty of several elements such as Al, Ba, Ca, Cu, Cr, Cd, Fe, Mg, Mn, Ni and K in water samples from Guarapiranga Dam. These elements were analyzed by optical emission spectrometry with inductively coupled plasma (ICP-OES). The value of relative estimated uncertainties were between 3% and 15%. The greatest uncertainty contributions were analytical curve, and the recovery method, which were related with elements concentrations and the equipment response. Water samples analyzed were compared with CONAMA Resolution #357/2005.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Uncertainty estimation in the determination of metals in superficial water by ICP-OES | 1092KB | download |