会议论文详细信息
9th International Conference on Inertial Fusion Sciences and Applications
Design of a north pole Neutron Time-of-Flight (NTOF) system at NIF
Caggiano, J.A.^1 ; Barbosa, F.^1 ; Clancy, T.J.^1 ; Eckart, M.J.^1 ; Grim, G.^1 ; Hartouni, E.P.^1 ; Hatarik, R.^1 ; Khater, H.^1 ; Lee, A.^1 ; Sampson, M.^1 ; Sayre, D.B.^1 ; Yeamans, C.^1 ; Yeoman, M.^1
Lawrence Livermore National Laboratory, Livermore
CA
94550, United States^1
关键词: Fast scintillator;    High sensitivity;    Line of Sight;    Lower energies;    Neutron spectroscopy;    Neutron time of flight;    Scattered neutron;    Target chamber center;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/717/1/012087/pdf
DOI  :  10.1088/1742-6596/717/1/012087
来源: IOP
PDF
【 摘 要 】
A north pole NTOF system for neutron spectroscopy is being implemented at the NIF. The design is centered around a fast scintillator with low mass housing fielded 21.6m from target chamber center at θ=18°,φ=304°. The line-of-sight (LOS) features a primary port collimator, two secondary collimators in the intervening concrete floors, and a beam dump with a backscatter shield. Because the detector is being fielded on the roof of the NIF building, diagnostic options such as optical and electrical attenuation are remotely controlled, saving setup time and increasing shot rate. The expected performance of the diagnostic is excellent with high sensitivity to both high-energy reaction-in-flight neutrons as well as lower energy down-scattered neutrons.
【 预 览 】
附件列表
Files Size Format View
Design of a north pole Neutron Time-of-Flight (NTOF) system at NIF 1379KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:19次