会议论文详细信息
Applications of Novel Scintillators for Research and Industry
Polycrystalline para-terphenyl scintillator adopted in a β? detecting probe for radio-guided surgery
物理学;工业技术
Solfaroli Camillocci, E.^1,2 ; Bellini, F.^1,2 ; Bocci, V.^2 ; Collamati, F.^2,3 ; De Lucia, E.^4 ; Faccini, R.^1,2 ; Marafini, M.^2,5 ; Mattei, I.^4,6 ; Morganti, S.^2 ; Paramatti, R.^2 ; Patera, V.^2,3 ; Pinci, D.^2 ; Recchia, L.^2 ; Russomando, A.^1,2,7 ; Sarti, A.^3,4 ; Sciubba, A.^2,3 ; Senzacqua, M.^1,2 ; Voena, C.^2
Dip. Fisica, Sapienza Univ. di Roma, Rome, Italy^1
INFN Sezione di Roma, Rome, Italy^2
Dip. Scienze di Base e Applicate per l'Ingegneria, Sapienza Univ. di Roma, Rome, Italy^3
Laboratori Nazionali di Frascati dell'Infn, Frascati (RM), Italy^4
Museo Storico della Fisica e Centro Studi e Ricerche e. Fermi, Rome, Italy^5
Dipartimento di Fisica, Università Roma Tre, Rome, Italy^6
Center for Life Nano Science at Sapienza, Istituto Italiano di Tecnologia, Rome, Italy^7
关键词: Activity ratios;    Intra-operative;    Organic scintillator;    Photo multiplier tube;    Polycrystalline;    Readout Electronics;    Remote monitoring;    Scintillation light;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/620/1/012009/pdf
DOI  :  10.1088/1742-6596/620/1/012009
学科分类:工业工程学
来源: IOP
PDF
【 摘 要 】
A radio-guided surgery technique exploiting β-emitters is under development. It aims at a higher target-to-background activity ratio implying both a smaller radiopharmaceutical activity and the possibility of extending the technique to cases with a large uptake of surrounding healthy organs. Such technique requires a dedicated intraoperative probe detecting β-radiation. A first prototype has been developed relying on the low density and high light yield of the diphenylbutadiene doped para-therphenyl organic scintillator. The scintillation light produced in a cylindrical crystal, 5 mm in diameter and 3 mm in height, is guided to a photo-multiplier tube by optical fibres. The custom readout electronics is designed to optimize its usage in terms of feedback to the surgeon, portability and remote monitoring of the signal. Tests show that with a radiotracer activity comparable to those administered for diagnostic purposes the developed probe can detect a 0.1 ml cancerous residual of meningioma in a few seconds.
【 预 览 】
附件列表
Files Size Format View
Polycrystalline para-terphenyl scintillator adopted in a β? detecting probe for radio-guided surgery 986KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:27次