会议论文详细信息
16th International Conference on Calorimetry in High Energy Physics
R&D for a highly granular silicon tungsten electromagnetic calorimeter
Pöschl, Roman^1
Laboratoire de l'Accélérateur Linéaire, Centre Scientifique d'Orsay, Bâtiment 200, Orsay
91898, France^1
关键词: Conceptual problems;    DAQ system;    Dynamic range;    Further works;    Granular silicon tungsten electromagnetic calorimeters;    Integrated applications;    Noise ratio;    Pulsed mode;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/587/1/012032/pdf
DOI  :  10.1088/1742-6596/587/1/012032
来源: IOP
PDF
【 摘 要 】

This article reports on first experience with the technological prototype of a highly- granular silicon-tungsten electromagnetic calorimeter as envisaged for the detectors at a future lepton collider. In the focus of the analysis is the performance of a highly integrated Application Specific Integrated Circuit designed to meet the requirements in terms of dynamic range, compactness and power consumption. The beam test results show that the circuit will allow a future detector with a signal over noise ratio of at least 10:1. To minimise the power dissipation the ASIC will be operated in a power pulsed mode. So far no conceptual problem was revealed but the studies show the way for further work. The prototype is read out by a DAQ system conceived to meet the needs of a trigger less system with a huge number of readout cells.

【 预 览 】
附件列表
Files Size Format View
R&D for a highly granular silicon tungsten electromagnetic calorimeter 10496KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:12次