会议论文详细信息
16th International Conference on Calorimetry in High Energy Physics
CMS Hadron Forward Calorimeter Phase I Upgrade Status
Onel, Yasar^1
University of Iowa, 203 Van Allen Hall, Iowa City
IA
52242, United States^1
关键词: Back ends;    Calorimeter resolutions;    Front end electronics;    Industrial standards;    MicroTCA;    Radiation hard;    Signal energy;    Window glass;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/587/1/012007/pdf
DOI  :  10.1088/1742-6596/587/1/012007
来源: IOP
PDF
【 摘 要 】

The CMS Hadronic Forward Calorimeter has undergone upgrade maintenance during the LHC Long Shutdown 1. The Hamamatsu R7525 PMTs have been replaced with Hamamatsu R7600U-200-M4 PMTs, which have thinner window glass that reduces window- hit events. The R7600 PMTs also have multi-anode readout feature to further enable discrimination of window-hits while also allowing the recovery of true signal energy. Higher quantum efficiency of the R7600 PMTs improves calorimeter resolution. The new PMTs were tested and calibrated; new PMT baseboards were designed and tested, and can be configured to readout 1, 2, or 4 anodes of the R7600. New radiation hard (100Gy) QIE front-end electronics were designed for reading out the new PMTs and include a TDC with

【 预 览 】
附件列表
Files Size Format View
CMS Hadron Forward Calorimeter Phase I Upgrade Status 4465KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:14次