| The Science of Making Torque from Wind 2014 | |
| Field-test results using a nacelle-mounted lidar for improving wind turbine power capture by reducing yaw misalignment | |
| Fleming, P.A.^1 ; Scholbrock, A.K.^1 ; Jehu, A.^2 ; Davoust, S.^2 ; Osler, E.^3 ; Wright, A.D.^1 ; Clifton, A.^1 | |
| National Renewable Energy Laboratory, Golden, CO 80401, United States^1 | |
| Avent Lidar Technology, Orsay, France^2 | |
| Renewable NRG Systems, Hinesburg, VT 05461, United States^3 | |
| 关键词: Field test; In-field; Normal operations; Power capture; Turbine performance; Wind direction measurement; Wind turbine power; | |
| Others : https://iopscience.iop.org/article/10.1088/1742-6596/524/1/012002/pdf DOI : 10.1088/1742-6596/524/1/012002 |
|
| 来源: IOP | |
PDF
|
|
【 摘 要 】
In this paper, a nacelle-mounted lidar was used to improve the yaw alignment of an experimental wind turbine. Using lidar-recorded data during normal operation, an error correction value for the nacelle vane wind direction measurement used in the yaw controller was determined. A field test was then conducted in which the turbine was operated with and without the correction applied to the yaw controller. Results demonstrated a significant increase in power capture. In addition, the study includes analysis on the impacts on loading of applying this yaw correction. The study demonstrates a successful application in field testing of using a nacelle-mounted lidar to improve turbine performance.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| Field-test results using a nacelle-mounted lidar for improving wind turbine power capture by reducing yaw misalignment | 3218KB |
PDF