20th International Conference on Computing in High Energy and Nuclear Physics | |
The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control System | |
物理学;计算机科学 | |
Holme, O.^1 ; Adzic, P.^2 ; Di Calafiori, D.^1 ; Dissertori, G.^1 ; Djambazov, L.^1 ; Jovanovic, D.^2 ; Lustermann, W.^1 ; Zelepoukine, S.^1,3 | |
Institute for Particle Physics, ETH Zurich, Zurich | |
8093, Switzerland^1 | |
University of Belgrade, Faculty of Physics, VINCA Institute of Nuclear Sciences, Serbia^2 | |
University of Wisconsin, Madison | |
WI | |
53706, United States^3 | |
关键词: Certification methods; Compact Muon solenoids; Detector control systems; Electromagnetic calorimeter; Hardware and software; Laboratory facilities; Large Hadron collider LHC; Operational experience; | |
Others : https://iopscience.iop.org/article/10.1088/1742-6596/513/1/012013/pdf DOI : 10.1088/1742-6596/513/1/012013 |
|
学科分类:计算机科学(综合) | |
来源: IOP | |
【 摘 要 】
The Electromagnetic Calorimeter (ECAL) is one of the sub-detectors of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) at CERN. The Detector Control System (DCS) that has been developed and implemented for the CMS ECAL was deployed in accordance with the LHC schedule and has been supporting the CMS data-taking since LHC physics runs started in 2009. During these years, the control system has been regularly adapted according to operational experience and new requirements, always respecting the constraints imposed on significant changes to a running system. Several hardware and software upgrades and system extensions were therefore deferred to the first LHC Long Shutdown (LS1). This paper presents the main architectural differences between the system that supported the CMS ECAL during its first years and the new design for the coming physics runs after LS1. Details on the upgrade planning, including the certification methods performed in the CMS ECAL DCS laboratory facilities, reports on the implementation progress and the expectations for the post-LS1 system are highlighted.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
The upgrade and re-validation of the Compact Muon Solenoid Electromagnetic Calorimeter Control System | 4526KB | download |