会议论文详细信息
18th APS-SCCM; 24th AIRAPT
Polycrystalline solids under nonhydrostatic compression: Determination of strength from x-ray diffraction data
Singh, A.K.^1
Materials Science Division, National Aerospace Laboratories, Bangalore
560 017, India^1
关键词: Confining pressures;    High-pressure diffraction;    Independent sources;    Polycrystalline samples;    Polycrystalline solid;    Pressure transmitting mediums;    Pressure-volume data;    X-ray diffraction data;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/500/12/122005/pdf
DOI  :  10.1088/1742-6596/500/12/122005
来源: IOP
PDF
【 摘 要 】

A polycrystalline sample compressed in a diamond anvil cell (DAC) without any pressure transmitting medium develops a stress state at the centre of the sample that is axially symmetric about the load axis. The axial stress component is larger than the radial component and the difference t between the two is taken as a measure of the compressive strength of the sample material at a confining pressure that equals the mean normal stress. A proper analysis of the diffraction data yields t. The data taken with the radial diffraction geometry, wherein the incident x-ray beam is perpendicular to the load axis of the DAC, give reliable estimates of strength. The diffraction data obtained with the conventional geometry, wherein the incident x-ray beam passes parallel to the DAC axis, provide reasonable estimates of strength. However, even in this case, reliable strength data can be obtained by combining the measured pressure-volume data under nonhydrostatic compression and the hydrostat derived from an independent source. The determination of strength from high pressure diffraction data is discussed.

【 预 览 】
附件列表
Files Size Format View
Polycrystalline solids under nonhydrostatic compression: Determination of strength from x-ray diffraction data 589KB PDF download
  文献评价指标  
  下载次数:9次 浏览次数:41次