会议论文详细信息
7th International Conference on 3D Radiation Dosimetry
Preliminary characterization of PRESAGE? for 3D dosimetry of 62 MeV proton beam
Gorjiara, T.^1 ; Kacperek, A.^2 ; Kuncic, Z.^1 ; Baldock, C.^1,4 ; Doran, S.^3
Institute of Medical Physics, School of Physics, University of Sydney, NSW 2006, Australia^1
Douglas Cyclotron, Clatterbridge Centre for Oncology, Wirral, United Kingdom^2
CRUK Clinical Magnetic Resonance Research Group, Institute of Cancer Research, Surrey, United Kingdom^3
Faculty of Science, Macquarie University, NSW 2109, Australia^4
关键词: 3d dosimeters;    Dose range;    Dose response;    Heavy particles;    Optical absorbance;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/444/1/012058/pdf
DOI  :  10.1088/1742-6596/444/1/012058
来源: IOP
PDF
【 摘 要 】

PRESAGE® has previously shown potential for 3D dosimetry of heavy particles. A new formulation has specifically developed for dosimetry of protons/heavy ions. This work provides a preliminary characterization the new formulation of PRESAGE® by measuring optical absorbance and dose response after irradiating by a 62 MeV proton beam for a dose range of 0.5 - 20 Gy. Results show linear dose response and the evolution over time of the optical density of the 3D dosimeter.

【 预 览 】
附件列表
Files Size Format View
Preliminary characterization of PRESAGE? for 3D dosimetry of 62 MeV proton beam 534KB PDF download
  文献评价指标  
  下载次数:11次 浏览次数:32次