会议论文详细信息
7th International Conference on 3D Radiation Dosimetry | |
Preliminary evaluation of diacetylene-based 3D micelle gel dosimeters | |
Nasr, A.^1 ; Olding, T.^2 ; Schreiner, L.J.^2,3 ; McAuley, K.B.^1 | |
Chemical Engineering Dept., Queen's University, Kingston, ON K7L 3N6, Canada^1 | |
Cancer Centre of Southeastern Ontario, Kingston, ON K7L 5P9, Canada^2 | |
Depts. of Oncology and Physics, Queen's University, Kingston, ON K7L 3N6, Canada^3 | |
关键词: Colour change; Diacetylenes; Gel dosimeter; Reporter molecules; Transparent gels; | |
Others : https://iopscience.iop.org/article/10.1088/1742-6596/444/1/012041/pdf DOI : 10.1088/1742-6596/444/1/012041 |
|
来源: IOP | |
【 摘 要 】
Emulsified diacetylenes as reporter molecules in micelle gel dosimeters were evaluated in the current article. It was observed that gels containing PCDA emulsified in deionized water using SDS changed from colourless to blue upon irradiation. Unfortunately, recipes that led to turbid gels resulted in a colour change, but transparent gels did not change colour. The colour change may be due to the oligomerization of precipitated solid PCA crystals, rather than emulsified PCDA.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Preliminary evaluation of diacetylene-based 3D micelle gel dosimeters | 1138KB | download |