会议论文详细信息
7th International Conference on 3D Radiation Dosimetry
4D dosimetry and its applications to pre-treatment quality control and real-time in vivo dosimetry of VMAT treatments
Nordström, F.^1 ; Af Wetterstedt, S.^1 ; Bäck, S.Å.J.^1
not available^1
关键词: 4d dosimetries;    Absorbed dose;    Clinical treatments;    Control point;    Dose distributions;    ITS applications;    Pre-Treatment;    Real time;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/444/1/012021/pdf
DOI  :  10.1088/1742-6596/444/1/012021
来源: IOP
PDF
【 摘 要 】

In this study, a 4D dosimetry concept was developed. This concept included a method for calculation of 3D reference absorbed dose matrices at every control point of the delivery using a clinical treatment planning system (TPS). Further, the gamma evaluation method was extended to incorporate the 4thdimension of the TPS calculated dose distributions. The applications of the 4D dosimetry concept on pre-treatment quality control and real-time in vivo dosimetry were investigated.

【 预 览 】
附件列表
Files Size Format View
4D dosimetry and its applications to pre-treatment quality control and real-time in vivo dosimetry of VMAT treatments 700KB PDF download
  文献评价指标  
  下载次数:17次 浏览次数:43次