会议论文详细信息
2nd International Symposium on Resource Exploration and Environmental Science
Influence of Shielding Plate on Operation Environment of Outdoor Unit of a Split-type Air-conditioner
生态环境科学
Su, Shunyu^1 ; Li, Chaoran^1
College of Urban Construction, Wuhan University of Science and Technology, Wuhan
430070, China^1
关键词: Air environment;    Air temperature;    Data acquisition system;    Environmental factors;    Installation methods;    Outdoor units;    Outlet air;    Split type air conditioner;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/170/3/032019/pdf
DOI  :  10.1088/1755-1315/170/3/032019
学科分类:环境科学(综合)
来源: IOP
PDF
【 摘 要 】

The air temperatures surrounding the outdoor unit of a split-type air-conditioner are very important environmental factors for its operation. Shielding plate can avoid the short circuit of inlet and outlet air. Under different installation methods of the outdoor units, the inlet and outlet air temperatures of the outdoor unit were measured by Keighley's Model 2700 data acquisition system in this paper. The results show that the air temperature of left inlet with shielding plate is lower than that without shielding plate. Therefore, the air temperature of front outlet with shielding plate is lower than that without shielding plate. The shielding plate installed between left and front has great influence on the air temperature of left inlet than on that of rear inlet. Shielding plate between the left inlet and the front outlet outside the outdoor unit of a split-type air-conditioner can improve the air environment of outdoor unit and benefit to the operation of the air-conditioner.

【 预 览 】
附件列表
Files Size Format View
Influence of Shielding Plate on Operation Environment of Outdoor Unit of a Split-type Air-conditioner 79KB PDF download
  文献评价指标  
  下载次数:11次 浏览次数:10次