【 摘 要 】
In this paper, a ion chromatographic method was established for simultaneously determining three toxic heavy metal ions(Ni2+, Pb2+, Cd2+) . The optimal chromatographic conditions are using a conductivity detector, with the Metrosep C4column was used, the mixture of 0.07mmol/L nitric acid and 0.5mmol/L dipicolinic acid as eluent, the flow rate was 0.25 mL/min. Three kinds of heavy metals all showed satisfying linear relationships, and the correlation coefficients ranged from 0.9979 to 0.9994. The detection limits were in the range of 0.01-0.05 mg/L. The method is an easy, accurate and reliable way to assess soil heavy metal pollution.