The results of a detailed measurement campaign on the effect of modifications to the pump compartment on spatial velocity profiles in vertically submersible pumps
Verhaart, F.I.H.^1 ; Zwanenburg, S.A.A.^1 ; De Fockert, A.^1
Deltares, PO Box 177, Delft
2600 MH, Netherlands^1
关键词: Curtain walls;    Local effects;    Measurement campaign;    Pumping stations;    Scale modeling;    Spatial deviation;    Spatial velocity;    Velocity profiles;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/22/3/032019/pdf
DOI  :  10.1088/1755-1315/22/3/032019
来源: IOP
PDF
【 摘 要 】

A detailed measurement campaign is performed in which the effect is determined of modifications to the pump compartment on the velocity profile in the suction pipe of a vertically submersible pump. These measurements are performed in a scale model of a simple pumping station of which the dimensions are equal to the ANSI/HI 9.8-2012 guidelines (HIS standard). A set of generally accepted modifications like splitters, fillings, curtain walls and baffles has been tested. The investigation showed that the acceptability of a velocity profile is not significantly influenced by these modifications (if well-designed). Some modifications have a local effect on the velocity profile. However, the locations with the largest spatial deviation, which determine the acceptability of the velocity profile, are not affected. Therefore, the statement in the HIS standard that small modifications to the pump compartment improve the velocity profile seems to be not generically valid.

【 预 览 】
附件列表
Files Size Format View
The results of a detailed measurement campaign on the effect of modifications to the pump compartment on spatial velocity profiles in vertically submersible pumps 1164KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:17次