会议论文详细信息
3rd International Symposium on Resource Exploration and Environmental Science
An Experimental Test To the High-Low-Voltage-Coupler Which Is Used In the Two-Sources-Driven Underwater Spark Acoustic Source
生态环境科学
Wang, Yibo^1 ; Zhang, Jinju^1 ; Peng, Fang^1
School of Electronic Information, Hunan Institute of Information Technology, ChangSha
410100, China^1
关键词: Acoustic sources;    Backward voltage;    Design Principles;    Experimental test;    Low voltages;    Peak values;    Right-hand sides;    Two sources;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/300/4/042096/pdf
DOI  :  10.1088/1755-1315/300/4/042096
学科分类:环境科学(综合)
来源: IOP
PDF
【 摘 要 】

In this paper, a new type of two-sources-driven underwater spark acoustic source (TSD-USAS), is suggested. Then, the main mechanism and design principle of the high-low-voltage-coupler, which is the key part of TSD-USAS, is discussed. Finally, an experimental measurement to the backward voltage-penetration of the high-low-voltage-coupler, is implemented (at conditions of the HV capacitor: C H = 1 μF, U 0 = 15 kV). The experimental results show that, when the HV discharge of the right-hand-side part (traditional USAS) leads to a non-breakdown, no apparent backward voltage-penetration will appear at the low voltage input terminal of the high-low-voltage-coupler; when leads to a breakdown, a backward voltage-penetration (peak value of +6200 V, pulse width of 17 μs) will arise.

【 预 览 】
附件列表
Files Size Format View
An Experimental Test To the High-Low-Voltage-Coupler Which Is Used In the Two-Sources-Driven Underwater Spark Acoustic Source 317KB PDF download
  文献评价指标  
  下载次数:11次 浏览次数:15次