Analysis and treatment of the shutdown reasons of ultra-supercritical 1000MW steam turbine generator set
生态环境科学
Li, Wanjun^1 ; Li, Xiaoxia^2 ; Huang, Tianqi^1 ; Niu, Qingliang^1
Huadian Electric Power Research Institute Co. LTD., Jinan
250014, China^1
CRRC Wind Power (ShanDong) CO. Ltd, Jinan
250022, China^2
关键词: Effective measures;    Fault analysis;    Fault treatment;    Feed pumps;    Leakage problems;    Maintenance records;    On-site inspection;    Steam turbine-generator set;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/300/4/042013/pdf
DOI  :  10.1088/1755-1315/300/4/042013
学科分类:环境科学(综合)
来源: IOP
PDF
【 摘 要 】

When a power plant ultra-supercritical 1000MW steam turbine generator set is running normally, the electric valve at the outlet of A steam feed pump appears serious leakage. Through on-site inspection and inspection of maintenance records, starting from the structure of the electric valve, the leakage fault of the electric valve at the outlet of A steam feed pump is diagnosed and investigated, and the cause of the fault is accurately analyzed. The leakage problem of the electric valve at the outlet of A steam feed pump has been thoroughly solved by taking effective measures such as changing the packing type, arrangement and improving the installation process.