会议论文详细信息
2019 3rd International Workshop on Renewable Energy and Development
Determination of Total Chlorine Content in Sewage Sludge
能源学;生态环境科学
Chen, L.M.^1^2 ; Liao, Y.F.^1^2^3 ; Ma, X.Q.^1^2
School of Electric Power, South China University of Technology, Guangzhou
510640, China^1
Guangdong Province Key Laboratory of Efficient and Clean Energy Utilization, Guangzhou
510640, China^2
Room 315, Building NO. 30, Wushan Campus, South China University of Technology, Guangzhou
510640, China^3
关键词: Bomb method;    Combined method;    Total chlorine;    Water extraction;    Water extraction methods;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/267/6/062010/pdf
DOI  :  10.1088/1755-1315/267/6/062010
学科分类:环境科学(综合)
来源: IOP
PDF
【 摘 要 】

Cl in sewage sludge may form HCl when burning, and caused acid rain or damaged the chemosphere; meanwhile, it could also enhanced the volatilization of heavy metals. It was important to know the Cl content in sewage sludge. The water extraction method, the Eschka method, the alkali absorption method, the oxygen bomb method, XRF, as well as their combined method were compared and the most suitable method to measure the Cl content in sludge was found. The water extraction- Eschka- alkali absorption method was the best method to measure the Cl content in sewage sludge, and had a good repeatability and veracity.