| 4th International Conference on Advances in Energy Resources and Environment Engineering | |
| Error Analysis of Calibration Length Baseline based on μ-base Distance Meter | |
| 能源学;生态环境科学 | |
| Gu, Youyi^1 ; Jiang, Lixing^1 ; Wang, Ancheng^1 ; Wang, Li^1 ; Ou, Yangwen^1 | |
| Information Engineering University, Zhengzhou, Henan | |
| 450001, China^1 | |
| 关键词: Analytical method; Calculation results; Comparative methods; Distance meters; Measurement methods; Meteorological parameters; Stable performance; Yellow river embankments; | |
| Others : https://iopscience.iop.org/article/10.1088/1755-1315/237/3/032022/pdf DOI : 10.1088/1755-1315/237/3/032022 |
|
| 学科分类:环境科学(综合) | |
| 来源: IOP | |
PDF
|
|
【 摘 要 】
This paper introduces in detail methods about calibration length baseline based on μ-base distance meter, and errors in the calculation of oblique distance model; the measurement of meteorological parameters and the correction of height difference are analyzed quantitatively by means of equation derivation. Through the calibration results of μ-base and invar tape, systematic differences between the two measurement methods were found out at the Yellow River Embankment Length Baseline in Zhengzhou. Based on a TS30 total station instrument with stable performance, according to the calculation results of "analytical method" and "comparative method", the accuracy of the two calibration results between μ-base and invar tape is compared and evaluated. In the end, some suggestions to improve the accuracy of using μ-base to calibrate length baseline are given.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| Error Analysis of Calibration Length Baseline based on μ-base Distance Meter | 796KB |
PDF