会议论文详细信息
2019 International Conference on Advanced Electronic Materials, Computers and Materials Engineering
Three Calculation Methods of the WGM Cylindrical Cavity Diameter
无线电电子学;计算机科学;材料科学
Li, Zhou^1 ; Guangyang, Xu^1 ; Jiufu, Chen^1 ; Lisha, Wang^1 ; Yao, Zhang^1
Zhaotong University, Collegel of Physics and Information Engineering, Zhaotong
657000, China^1
关键词: Approximate formulas;    Circular cavity;    Cylindrical cavities;    First-order approximations;    Mode fields;    Resonance peak;    Second-order approximation;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/563/5/052012/pdf
DOI  :  10.1088/1757-899X/563/5/052012
来源: IOP
PDF
【 摘 要 】

WGM mode in cylindrical cavity can be rapidly calibrated with analytical approximate formulas based on cylindrical micro-cavity WGM resonance peaks position. On this basis, the diameter of circular cavity can be calculated by applying the three methods, which are the first-order approximation method, the second-order approximation method and mode field radius. When comparing the results which are got from the three methods with the actual geometric diameter, we find that the deviation is within 3%, 2%, 1% respectively. As a result, the diameter of circular cavity can be correctly worked out by making use of these three ways mentioned.

【 预 览 】
附件列表
Files Size Format View
Three Calculation Methods of the WGM Cylindrical Cavity Diameter 404KB PDF download
  文献评价指标  
  下载次数:17次 浏览次数:10次