会议论文详细信息
25th International Conference and Meeting of Departments, CONSTRUMAT 2019
Assessment of the resistance of ventilated facade system by vacuum testing
Schmid, P.^1 ; Dank, P.^1 ; Rozsypalová, I.^1 ; Holomek, P.^1 ; Juránek, P.^2
Brno University of Technology, Faculty of Civil Engineering, Veveí 331/95, Brno
602 00, Czech Republic^1
Brno Branch, Technical and Test Institute for Construction Prague, SOE (TZÚS Praha, S. P.), Hnvkovského 228/77, Brno, Czech Republic^2
关键词: Exposed to;    Load bearing;    Loading system;    Mechanical resistance;    Sub-frame;    Vacuum testing;    Wind suction;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/549/1/012034/pdf
DOI  :  10.1088/1757-899X/549/1/012034
来源: IOP
PDF
【 摘 要 】

The aim of this research was to determine experimentally the mechanical resistance of preset ventilated facade systems exposed to wind suction. In accordance with the European ETAG 034 Guideline, Part 1, seven facade assemblies were tested. The wind suction load was simulated in a vacuum test in the AdMaS centre using the universal vacuum loading system. The test was performed with a load increasing in increments, where after each level, the specimens were unloaded. The effect of the density of connections of load-bearing plates with the structure of subframes was demonstrated. Further, the resistance to wind suction of specimens with timber subframe was slightly higher than that of specimens with aluminium subframe.

【 预 览 】
附件列表
Files Size Format View
Assessment of the resistance of ventilated facade system by vacuum testing 1350KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:7次