会议论文详细信息
27th International Cryogenics Engineering Conference and International Cryogenic Materials Conference 2018
Design of a half-size 3T REBCO superconducting magnet with active shielding coils for MRI
Yokoyama, S.^1 ; Miura, H.^1 ; Matsuda, T.^1 ; Inoue, T.^2 ; Morita, Y.^2 ; Otake, S.^2 ; Sato, S.^1
Advanced Technology R and D Center, Mitsubishi Electric Corporation, Amagasaki, HYOGO
661-8661, Japan^1
Transmission and Distribution Systems Center, Mitsubishi Electric Corporation, Ako, HYOGO
678-0256, Japan^2
关键词: Active shielding;    Calculation results;    Electromagnetic stress;    High magnetic fields;    Mri superconducting magnets;    New energy and industrial technology development organizations;    Optimal design methods;    Research and development;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/502/1/012101/pdf
DOI  :  10.1088/1757-899X/502/1/012101
来源: IOP
PDF
【 摘 要 】

Research and development for the practical application of a medical-use MRI superconducting magnet that requires without liquid helium started as the New Energy and Industrial Technology Development Organization's (NEDO) supported project in fiscal 2016. This project will test produce a halfsize active shield-Type 3T REBCO coil and realize high magnetic field homogeneity and stability. To achieve this, issues will be resolved by developing the optimal design method for the coil system, establishing a coil manufacture method, stabilizing the magnetic field, and protecting the coil. We will describe the structure and fabrication conditions of the 3T REBCO coil, calculation results of electromagnetic stress. Cooling system design of this coil is also described.

【 预 览 】
附件列表
Files Size Format View
Design of a half-size 3T REBCO superconducting magnet with active shielding coils for MRI 484KB PDF download
  文献评价指标  
  下载次数:17次 浏览次数:13次