会议论文详细信息
27th International Cryogenics Engineering Conference and International Cryogenic Materials Conference 2018 | |
Minimising flow losses within the pulse tube of a Stirling pulse tube cryocooler | |
Abolghasemi, M.A.^1 ; Stone, R.^1 ; Dadd, M.^1 ; Bailey, P.^1 ; Liang, K.^2 | |
Department of Engineering Science, University of Oxford, United Kingdom^1 | |
Department of Engineering and Design, University of Sussex, United Kingdom^2 | |
关键词: Flow loss; Flow straightener; Flow-mixing; Navier-Stokes solver; Pulse tube cryocoolers; Pulse tubes; RANS turbulence models; Stirling pulse tube cryocooler; | |
Others : https://iopscience.iop.org/article/10.1088/1757-899X/502/1/012044/pdf DOI : 10.1088/1757-899X/502/1/012044 |
|
来源: IOP | |
![]() |
【 摘 要 】
Successful operation of Stirling pulse tube cryocoolers relies on minimising flow mixing within the pulse tube. Hence, the pulse tube and the flow straighteners at either end must be designed with great care. In this study, the flow within the pulse tube of an existing Stirling pulse tube cryocooler is numerically analysed and alternative flow straightener designs are suggested. The numerical simulation have been carried out using CONVERGE CFD, a finite volume Navier-Stokes solver. The standard k- RANS turbulence model has been used to account for the effects of turbulence within the pulse tube.【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Minimising flow losses within the pulse tube of a Stirling pulse tube cryocooler | 897KB | ![]() |