会议论文详细信息
2nd International (15th Regional) Scientific Conference "Technogenic Systems and Environmental Risk"
Experimental and theoretical assessment of power frequency electric field individual protective means
工业技术(总论);生态环境科学
Perov, S.Yu.^1 ; Belaya, O.V.^1 ; Khrennikova, T.A.^1
FSBSI izmerov Research Institute of Occupational Health, Moscow, Russia^1
关键词: Electric filed;    Human body tissues;    Induced electric fields;    Limit values;    Power frequency electric field;    Typical samples;    Worker safety;   
Others  :  https://iopscience.iop.org/article/10.1088/1757-899X/487/1/012031/pdf
DOI  :  10.1088/1757-899X/487/1/012031
来源: IOP
PDF
【 摘 要 】

Electromagnetic field levels at workplaces may exceed permissible limit values. In this case the individual protective means use obligatory. There are presented the date of typical samples of conductive suits (under work in power frequency electric field) testing by simulation and in experiment. Individual protective means screening factors were changed from 42.26 to 52.43 dB. The averaged electric field level inside of conductive suit was 220 mV/m in case of simulation. The induced electric fields in human body tissues with conductive suit were 0.003-0.150 V/m. The results show that conductive suit use allows reducing the induced electric filed levels and ensures worker safety.

【 预 览 】
附件列表
Files Size Format View
Experimental and theoretical assessment of power frequency electric field individual protective means 1040KB PDF download
  文献评价指标  
  下载次数:23次 浏览次数:24次